About Noxivent 102

What is this medication? Noxivent is a prescription medication consisting of inhaled nitric oxide gas, which is used primarily in a hospital setting for newborn infants. It is specifically indicated for the treatment of term and near-term neonates who are experiencing hypoxic respiratory failure. This condition occurs when an infant’s blood does not carry enough oxygen to meet the body’s needs, often requiring intensive medical intervention. The gas is delivered through a specialized breathing machine to help stabilize the infant’s oxygen levels and support their overall respiratory function. The medication works as a selective pulmonary vasodilator, meaning it helps to relax and widen the blood vessels specifically within the lungs. By opening these vessels, it reduces pulmonary blood pressure and allows more blood to reach the areas of the lung where oxygen exchange occurs. This process significantly improves oxygenation in the blood and is particularly effective for babies whose respiratory failure is linked to pulmonary hypertension. By improving the efficiency of the lungs, Noxivent can help reduce the need for high-risk treatments like extracorporeal membrane oxygenation.

Copay & patient assistance

Detailed copay and financial assistance information is not publicly available for this medication at this time. Please consult your pharmacist or the manufacturer's official patient support program for more details.

External links go directly to the manufacturer's portal. RxCopays does not receive compensation for referrals.

Compare pricing elsewhere

RxCopays doesn't sell drugs or take referral fees. Here are the transparent-pricing directories we recommend checking alongside your insurance formulary.

We deep-link because transparency helps patients. None of these partners pay RxCopays.

Prescribing information

From the FDA-approved label for Noxivent 102. Official source: DailyMed (NLM) · Label effective Nov 13, 2025

Indications and usage
INDICATIONS AND USAGE Noxivent™ is a vasodilator indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents. 1. INDICATIONS AND USAGE Noxivent™ is indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents.
Dosage and administration
DOSAGE AND ADMINISTRATION The recommended dose is 20 ppm, maintained for up to 14 days or until the underlying oxygen desaturation has resolved ( 2.1 ). Doses greater than 20 ppm are not recommended ( 2.1 , 5.2 ) Administration: • Avoid abrupt discontinuation ( 2.2 , 5.1 ). 2. DOSAGE AND ADMINISTRATION 2.1 Dosage Term and near-term neonates with hypoxic respiratory failure The recommended dose of Noxivent™ is 20 ppm. Maintain treatment up to 14 days or until the underlying oxygen desaturation has resolved and the neonate is ready to be weaned from Noxivent™ therapy. Doses greater than 20 ppm are not recommended [see Warnings and Precautions (5.2) ]. 2.2 Administration Nitric Oxide Delivery Systems Noxivent™ must be administered using a calibrated FDA-cleared Nitric Oxide Delivery System (NODS). There are various FDA-cleared NODS; refer to the NODS labeling to determine which NODS to use with this drug product and for needed information on training and technical support for users of this drug product with the NODS. Do not use Noxivent with Inomax DSIR Plus and DSIP MRI NODS. Do not use Noxivent in the MPI suite. Keep available a backup battery power supply and an independent reserve nitric oxide delivery system to address power and system failures. Monitoring Measure methemoglobin within 4-8 hours after initiation of treatment with Noxivent™ and periodically throughout treatment [see Warnings and Precautions (5.2 )]. Monitor for PaO 2 and inspired NO 2 during Noxivent™ administration [see Warnings and Precautions 5.3 )]. Weaning and Discontinuatio n Avoid abrupt discontinuation of Noxivent™ [see Warnings and Precautions (5.1 )]. To wean Noxivent™, downtitrate in several steps, pausing several hours at each step to monitor for hypoxemia.
Contraindications
CONTRAINDICATIONS Neonates dependent on right-to-left shunting of blood ( 4 ). 4. CONTRAINDICATIONS Noxivent™ is contraindicated in neonates dependent on right-to-left shunting of blood.
Warnings and precautions
WARNINGS AND PRECAUTIONS Rebound: Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure ( 5.1 ). Methemoglobinemia: Methemoglobin increases with the dose of nitric oxide; following discontinuation or reduction of nitric oxide, methemoglobin levels return to baseline over a period of hours ( 5.2 ). Elevated NO 2 Levels: Monitor NO 2 levels ( 5.3 ). Heart Failure: In patients with pre-existing left ventricular dysfunction, Noxivent™ may increase pulmonary capillary wedge pressure leading to pulmonary edema ( 5.4 ). 5. WARNINGS AND PRECAUTIONS 5.1 Rebound Pulmonary Hypertension Syndrome following Abrupt Discontinuation Wean from Noxivent™ [see Dosage and Administration (2.2 )]. Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure, i.e., Rebound Pulmonary Hypertension Syndrome. Signs and symptoms of Rebound Pulmonary Hypertension Syndrome include hypoxemia, systemic hypotension, bradycardia, and decreased cardiac output. If Rebound Pulmonary Hypertension occurs, reinstate Noxivent™ therapy immediately. 5.2 Hypoxemia from Methemoglobinemia Nitric oxide combines with hemoglobin to form methemoglobin, which does not transport oxygen. Methemoglobin levels increase with the dose of Noxivent™; it can take 8 hours or more before steady-state methemoglobin levels are attained. Monitor methemoglobin and adjust the dose of Noxivent™ to optimize oxygenation. If methemoglobin levels do not resolve with decrease in dose or discontinuation of Noxivent™, additional therapy may be warranted to treat methemoglobinemia [see Overdosage (10 )]. 5.3 Airway Injury from Nitrogen Dioxide Nitrogen dioxide (NO 2 ) forms in gas mixtures containing NO and O 2 . Nitrogen dioxide may cause airway inflammation and damage to lung tissues. If there is an unexpected change in NO 2 concentration, or if the NO 2 concentration reaches 3 ppm when measured in the breathing circuit, then the delivery system should be assessed in accordance with the Nitric Oxide Delivery System O&M Manual troubleshooting section, and the NO 2 analyzer should be recalibrated. The dose of Noxivent™ and/or FiO 2 should be adjusted as appropriate. 5.4 Worsening Heart Failure Patients with left ventricular dysfunction treated with Noxivent™ may experience pulmonary edema, increased pulmonary capillary wedge pressure, worsening of left ventricular dysfunction, systemic hypotension, bradycardia and cardiac arrest. Discontinue Noxivent™ while providing symptomatic care.
Drug interactions
DRUG INTERACTIONS Nitric oxide donor compounds may increase the risk of developing methemoglobinemia ( 7 ). Revised: 08/2023 7. DRUG INTERACTIONS 7.1 Nitric Oxide Donor Agents Nitric oxide donor agents such as prilocaine, sodium nitroprusside and nitroglycerine may increase the risk of developing methemoglobinemia.
Adverse reactions
ADVERSE REACTIONS The most common adverse reaction is hypotension. ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact Linde, Inc. at 1-800-772-9247 and www.linde.com or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch . 6. ADVERSE REACTIONS The following adverse reactions are discussed elsewhere in the label; Hypoxemia [see Warnings and Precautions (5.2 )] Worsening Heart Failure [see Warnings and Precautions (5.4 )] 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The adverse reaction information from the clinical studies does, however, provide a basis for identifying the adverse events that appear to be related to drug use and for approximating rates. Controlled studies have included 325 patients on nitric oxide doses of 5 to 80 ppm and 251 patients on placebo. Total mortality in the pooled trials was 11% on placebo and 9% on nitric oxide, a result adequate to exclude nitric oxide mortality being more than 40% worse than placebo. In both the NINOS and CINRGI studies, the duration of hospitalization was similar in nitric oxide and placebo-treated groups. From all controlled studies, at least 6 months of follow-up is available for 278 patients who received nitric oxide and 212 patients who received placebo. Among these patients, there was no evidence of an adverse effect of treatment on the need for rehospitalization, special medical services, pulmonary disease, or neurological sequelae. In the NINOS study, treatment groups were similar with respect to the incidence and severity of intracranial hemorrhage, Grade IV hemorrhage, periventricular leukomalacia, cerebral infarction, seizures requiring anticonvulsant therapy, pulmonary hemorrhage, or gastrointestinal hemorrhage. In CINRGI, the only adverse reaction (>2% higher incidence on nitric oxide than on placebo) was hypotension (14% vs. 11%). 6.2 Post-Marketing Experience Post marketing reports of accidental exposure to nitric oxide for inhalation in hospital staff has been associated with chest discomfort, dizziness, dry throat, dyspnea, and headache.
Use in pregnancy
8. USE IN SPECIFIC POPULATIONS 8.4 Pediatric Use The safety and efficacy of nitric oxide for inhalation has been demonstrated in term and near-term neonates with hypoxic respiratory failure associated with evidence of pulmonary hypertension [see Clinical Studies (14.1 )]. Additional studies conducted in premature neonates for the prevention of bronchopulmonary dysplasia have not demonstrated substantial evidence of efficacy [see Clinical Studies (14.3 )]. No information about its effectiveness in other age populations is available. 8.5 Geriatric Use Nitric oxide is not indicated for use in the adult population.

Label text is reproduced as-is from the FDA-approved label. We do not paraphrase, summarize, or omit. Content above is for informational purposes only and is not medical advice. Always consult your prescribing clinician or pharmacist before making decisions about your medication.

Conditions we've indexed resources for

Click a condition to see copay cards, grants, and PA rules specific to it. For the full list of FDA-approved indications, see Prescribing information above.

Prior authorization & coverage

PayerPAStep therapyCopay tier

Medicare Part D

Related drugs

How this page is sourced

  • Drug identity verified against openFDA NDC Directory.
  • Label text (when shown) originates from NLM DailyMed.
  • Copay and assistance URLs verified periodically; if you hit a broken link, tell us.