DURYSTA

Generic: bimatoprost

Verified·Apr 23, 2026
Manufacturer
AbbVie
NDC
0023-9652
RxCUI
2286602
Route
INTRACAMERAL
ICD-10 indication
H40.10X0

Affordability Check

How much will you actually pay for DURYSTA?

In 30 seconds, see every legitimate way to afford DURYSTA — Medicare copay, manufacturer copay card, Patient Assistance Program, grants, or cash.

Check my options →

About DURYSTA

What is this medication?

DURYSTA is a prescription medication used to reduce internal eye pressure in adults who have open-angle glaucoma or ocular hypertension. It is a tiny, biodegradable implant that contains bimatoprost, which is a medicine that helps lower intraocular pressure by increasing the drainage of fluid from the eye. By maintaining lower pressure levels, the medication helps to manage these conditions and protect against the progression of vision loss.

Instead of being applied as a daily eye drop, this medication is a single-use implant that is placed directly into the eye by an eye doctor during a professional procedure. Once the implant is positioned, it slowly releases the medication as it dissolves over time, providing continuous treatment for several months. This delivery method is specifically designed to help patients who may have difficulty adhering to a daily eye drop regimen.

Copay & patient assistance

  • Patient Copay Amount: Not Publicly Available
  • Maximum Annual Benefit Limit: Not Publicly Available
  • Core Eligibility Restrictions: Not Publicly Available
  • RxBIN, PCN, and Group numbers: Not Publicly Available

External links go directly to the manufacturer's portal. RxCopays does not receive compensation for referrals.

Compare pricing elsewhere

RxCopays doesn't sell drugs or take referral fees. Here are the transparent-pricing directories we recommend checking alongside your insurance formulary.

We deep-link because transparency helps patients. None of these partners pay RxCopays.

Prescribing information

From the FDA-approved label for DURYSTA. Official source: DailyMed (NLM) · Label effective Oct 16, 2024

Indications and usage
1 INDICATIONS AND USAGE DURYSTA ® (bimatoprost intracameral implant) is indicated for the reduction of intraocular pressure (IOP) in patients with open angle glaucoma (OAG) or ocular hypertension (OHT). DURYSTA is a prostaglandin analog indicated for the reduction of intraocular pressure (IOP) in patients with open angle glaucoma (OAG) or ocular hypertension (OHT). ( 1 )
Dosage and administration
2 DOSAGE AND ADMINISTRATION For ophthalmic intracameral administration. ( 2.1 ) The intracameral administration should be carried out under standard aseptic conditions. ( 2.2 ) Figure 1 Figure 2 2. 1 General Information DURYSTA is an ophthalmic drug delivery system for a single intracameral administration of a biodegradable implant. DURYSTA should not be readministered to an eye that received a prior DURYSTA. 2.2 Administration The intracameral injection procedure must be performed under magnification that allows clear visualization of the anterior chamber structures and should be carried out using standard aseptic conditions for intracameral procedures, with the patient’s head in a stabilized position. The eye should not be dilated prior to the procedure. Remove the foil pouch from the carton and examine for damage. Then, open the foil pouch over a sterile field and gently drop the applicator on a sterile tray. Once the foil pouch is opened, use the applicator promptly. Figure 1 Perform a detailed visual inspection of the applicator, including ensuring that the actuator button has not been depressed, and the safety tab is in place. Carefully remove the plastic safety cap taking care to avoid contacting the needle tip. Inspect the needle tip for damage under magnification prior to use; the implant retention plug may be visible in the bevel and should not be removed. Prior to use, remove the safety tab by pulling it out perpendicular to the long axis of the applicator (refer to Figure 1a above). Do not twist or bend the tab. Stabilize the eye as the needle is advanced through the cornea. Enter the anterior chamber with the needle bevel visible through clear cornea. Enter parallel to the iris plane, adjacent to the limbus through clear cornea in the superotemporal quadrant. The needle should be inserted approximately 2 bevel lengths with the bevel completely within the anterior chamber; avoid positioning the needle bevel directly over the pupil. Ensure the needle is not bent before depressing the actuator button. See Figure 2. Figure 2 Depress the back half of the actuator button (refer to Figure 1b above) firmly until an audible and/or palpable click is noted. Following the release of the implant, remove the needle via the same track in which it was inserted and tamponade the opening. The implant should not be left in the corneal injection track. Check the injection site for leaks; make sure that it is self-sealing and the anterior chamber is formed. After injection, do not recap the needle. Dispose of the used applicator in a sharps disposal container and in accordance with local requirements. Instruct the patient to remain upright for at least 1 hour after the procedure so the implant can settle. Some degree of eye redness and discomfort is expected following administration. However, it is recommended to instruct patients that if the eye becomes progressively red, sensitive to light, painful, or develops a change in vision, they should immediately contact the physician.
Contraindications
4 CONTRAINDICATIONS Ocular or periocular infections ( 4.1 ) Corneal endothelial cell dystrophy ( 4.2 ) Prior corneal transplantation ( 4.3 ) Absent or ruptured posterior lens capsule ( 4.4 ) Hypersensitivity ( 4.5 ) 4.1 Ocular or Periocular Infections DURYSTA is contraindicated in patients with active or suspected ocular or periocular infections. 4.2 Corneal Endothelial Cell Dystrophy DURYSTA is contraindicated in patients with corneal endothelial cell dystrophy (e.g., Fuchs’ Dystrophy) [ see Warnings and Precautions ( 5.1 ) ] . 4.3 Prior Corneal Transplantation DURYSTA is contraindicated in patients with prior corneal transplantation, or endothelial cell transplants [e.g., Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK)]. 4.4 Absent or Ruptured Posterior Lens Capsule DURYSTA is contraindicated in patients whose posterior lens capsule is absent or ruptured, due to the risk of implant migration into the posterior segment. Laser posterior capsulotomy in pseudophakic patients is not a contraindication for DURYSTA use if the intraocular lens fully covers the opening in the posterior capsule. 4.5 Hypersensitivity DURYSTA is contraindicated in patients with hypersensitivity to bimatoprost or to any other components of the product [ see Adverse Reactions ( 6.1 ) ] .
Warnings and precautions
5 WARNINGS AND PRECAUTIONS Endothelial cell loss : Due to possible corneal endothelial cell loss, administration of DURYSTA should be limited to a single implant per eye without retreatment. ( 5.1 ) Corneal Adverse Reactions : DURYSTA has been associated with corneal adverse reactions and risks are increased with multiple implants. Use caution in patients with limited corneal endothelial cell reserve. ( 5.1 ) Iridocorneal Angle : DURYSTA should be used with caution in patients with narrow angles or anatomical angle obstruction. ( 5.2 ) 5.1 Corneal Adverse Reactions The presence of DURYSTA implants has been associated with corneal adverse reactions and increased risk of corneal endothelial cell loss. Administration of DURYSTA should be limited to a single implant per eye without retreatment. Caution should be used when prescribing DURYSTA in patients with limited corneal endothelial cell reserve. 5.2 Iridocorneal Angle Following administration with DURYSTA, the intracameral implant is intended to settle within the inferior angle. DURYSTA should be used with caution in patients with narrow iridocorneal angles (Shaffer grade ˂ 3) or anatomical obstruction (e.g., scarring) that may prohibit settling in the inferior angle. 5.3 Macular Edema Macular edema, including cystoid macular edema, has been reported during treatment with ophthalmic bimatoprost, including DURYSTA intracameral implant. DURYSTA should be used with caution in aphakic patients, in pseudophakic patients with a torn posterior lens capsule, or in patients with known risk factors for macular edema. 5.4 Intraocular Inflammation Prostaglandin analogs, including DURYSTA, have been reported to cause intraocular inflammation. DURYSTA should be used with caution in patients with active intraocular inflammation (e.g., uveitis) because the inflammation may be exacerbated. 5.5 Pigmentation Ophthalmic bimatoprost, including DURYSTA intracameral implant, has been reported to cause changes to pigmented tissues, such as increased pigmentation of the iris. Pigmentation of the iris is likely to be permanent. Patients who receive treatment should be informed of the possibility of increased pigmentation. The pigmentation change is due to increased melanin content in the melanocytes rather than to an increase in the number of melanocytes. While treatment with DURYSTA can be continued in patients who develop noticeably increased iris pigmentation, these patients should be examined regularly. 5.6 Endophthalmitis Intraocular surgical procedures and injections, including DURYSTA, have been associated with endophthalmitis. Proper aseptic technique must always be used with administering DURYSTA, and patients should be monitored following the administration.
Adverse reactions
6 ADVERSE REACTIONS The following clinically significant adverse reactions are described elsewhere in labeling: Implant migration [see Contraindications ( 4.4 )] Hypersensitivity [ see Contraindications ( 4.5 ) ] Corneal adverse reactions [ see Warnings and Precautions ( 5.1 ) ] Macular edema [ see Warnings and Precautions ( 5.3 ) ] Intraocular inflammation [ see Warnings and Precautions ( 5.4 ) ] Pigmentation [ see Warnings and Precautions ( 5.5 ) ] Endophthalmitis [ see Warnings and Precautions ( 5.6 ) ] In controlled studies, the most common ocular adverse reaction reported by 27% of patients was conjunctival hyperemia. Other common adverse reactions reported in 5-10% of patients were foreign body sensation, eye pain, photophobia, conjunctival hemorrhage, dry eye, eye irritation, intraocular pressure increased, corneal endothelial cell loss, vision blurred, iritis, and headache. ( 6.1 ) To report SUSPECTED ADVERSE REACTIONS, contact AbbVie at 1-800-678-1605 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The most common ocular adverse reaction observed in two randomized, active-controlled clinical trials with DURYSTA in patients with OAG or OHT was conjunctival hyperemia, which was reported in 27% of patients. Other common ocular adverse reactions reported in 5-10% of patients were foreign body sensation, eye pain, photophobia, conjunctival hemorrhage, dry eye, eye irritation, intraocular pressure increased, corneal endothelial cell loss, vision blurred, and iritis. Ocular adverse reactions occurring in 1-5% of patients were anterior chamber cell, lacrimation increased, corneal edema, aqueous humor leakage, iris adhesions, ocular discomfort, corneal touch, iris hyperpigmentation, anterior chamber flare, anterior chamber inflammation, and macular edema. The following additional adverse drug reactions occurred in less than 1% of patients: hyphema, iridocyclitis, uveitis, corneal opacity, corneal thickening, product administered at inappropriate site, corneal decompensation, cystoid macular edema, and drug hypersensitivity. The most common nonocular adverse reaction was headache, which was observed in 5% of patients. 6.2 Postmarketing Experience The following adverse reactions have been identified during postapproval use of DURYSTA. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Eye disorders : endophthalmitis
Use in pregnancy
8.1 Pregnancy Risk Summary There are no adequate and well-controlled studies of DURYSTA (bimatoprost intracameral implant) administration in pregnant women to inform a drug associated risk. Oral administration of bimatoprost to pregnant rats and mice throughout organogenesis did not produce adverse maternal or fetal effects at clinically relevant exposures. Oral administration of bimatoprost to rats from the start of organogenesis to the end of lactation did not produce adverse maternal, fetal or neonatal effects at clinically relevant exposures [see Animal Data] . Data Animal Data In an embryofetal development rat study, oral administration of bimatoprost to pregnant rats during organogenesis produced abortion at 0.6 mg/kg/day (1770-times the human systemic exposure to bimatoprost from DURYSTA, based on C max and a blood-to plasma partition ratio of 0.858). The No Observed Adverse Effect Level (NOAEL) for abortion was 0.3 mg/kg/day (estimated at 470-times the human systemic exposure to bimatoprost from DURYSTA, based on C max ). No fetal abnormalities were observed at doses up to 0.6 mg/kg/day. In an embryofetal development mouse study, oral administration of bimatoprost to pregnant mice during organogenesis produced abortion and early delivery at 0.3 mg/kg/day (2240-times the human systemic exposure to bimatoprost from DURYSTA, based on plasma C max level; blood-to plasma partition ratio of 0.858). The NOAEL for abortion and early delivery was 0.1 mg/kg/day (400-times the human systemic exposure to bimatoprost from DURYSTA, based on C max ). No fetal abnormalities were observed at doses up to 0.6 mg/kg/day (5200-times the human systemic exposure to bimatoprost from DURYSTA, based on C max ). In a pre/postnatal development study, oral administration of bimatoprost to pregnant rats from gestation day 7 through lactation resulted in reduced gestation length, increased late resorptions, fetal deaths, and postnatal pup mortality, and reduced pup body weight at 0.3 mg/kg/day (estimated 470-times the human systemic exposure to bimatoprost from DURYSTA, based plasma C max and a blood-to plasma partition ratio of 0.858). No adverse effects were observed in rat offspring at 0.1 mg/kg/day (estimated 350-times the human systemic exposure to bimatoprost from DURYSTA, based on plasma C max ).

Label text is reproduced as-is from the FDA-approved label. We do not paraphrase, summarize, or omit. Content above is for informational purposes only and is not medical advice. Always consult your prescribing clinician or pharmacist before making decisions about your medication.

Conditions we've indexed resources for

Click a condition to see copay cards, grants, and PA rules specific to it. For the full list of FDA-approved indications, see Prescribing information above.

Prior authorization & coverage

PayerPAStep therapyCopay tier

Medicare Part D

Related drugs

How this page is sourced

  • Drug identity verified against openFDA NDC Directory.
  • Label text (when shown) originates from NLM DailyMed.
  • Copay and assistance URLs verified periodically; if you hit a broken link, tell us.